Grade – BI 14/1,3

TECHNICAL DATA SHEET
Name of the product: insulating concrete
Classification: BI 14/1,3
Properties Unit BI 14/1,3 BI 14/1,3
Method of application cast gun
Temperature limit of application, max oC 1400 1400
Cold crushing strength, min

  • After drying at 105 oC, min
  • After firing at the temperature of application after 2 h, min
MPa 12,0
4,5
13,0
5,5
Bulk density after firing at temperature limit of application, min g/cm3 1,3 1,35
Thermal conductivity:

  • 400 ºC
  • 600 ºC
  • 800 ºC
  • 1000 ºC
W/mK

 

0,42


0,55

 

0,43


0,59

The indicated technical data are for information only and are not to be viewed as guaranteed values.